<?xml version="1.0" encoding="UTF-8"?>
<netcdf xmlns="http://www.unidata.ucar.edu/namespaces/netcdf/ncml-2.2" location="Not provided because of security concerns.">
  <attribute name="Conventions" value="CF-1.8, ACDD-1.3" />
  <attribute name="featureType" value="timeSeries" />
  <attribute name="title" value="Ground based in situ observations of chemiluminescence_photolytic at SIRTA Atmospheric Research Observatory (FR0020R)" />
  <attribute name="keywords" value="nitrogen_dioxide, SIRTA Atmospheric Research Observatory, mole_fraction_of_nitrogen_monoxide_in_air, FR0020R, GAW-WDCA, ACTRIS, air, nitrogen_monoxide, mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air, mole_fraction_of_nitrogen_dioxide_in_air, mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air, EMEP" />
  <attribute name="id" value="8Q72-YCBM.nc" />
  <attribute name="naming_authority" value="EBAS" />
  <attribute name="project" value="ACTRIS, EMEP, GAW-WDCA" />
  <attribute name="acknowledgement" value="Request acknowledgement details from data originator" />
  <attribute name="doi" value="https://doi.org/10.48597/8Q72-YCBM" />
  <attribute name="license" value="https://creativecommons.org/licenses/by/4.0/" />
  <attribute name="citation" value="Valerie Gros, Nicolas Bonnaire, nitrogen_dioxide, nitrogen_monoxide - chemiluminescence_photolytic at SIRTA Atmospheric Research Observatory, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/8Q72-YCBM" />
  <attribute name="summary" value="Ground based in situ observations of chemiluminescence_photolytic at SIRTA Atmospheric Research Observatory (FR0020R). These measurements are gathered as a part of the following projects ACTRIS, EMEP, GAW-WDCA and they are stored in the EBAS database (http://ebas.nilu.no/). Parameters measured are: nitrogen_dioxide in air (mole_fraction_of_nitrogen_dioxide_in_air), nitrogen_dioxide in air (mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air), nitrogen_dioxide in air (mole_fraction_of_nitrogen_dioxide_in_air), nitrogen_dioxide in air (mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air), nitrogen_dioxide in air (mole_fraction_of_nitrogen_dioxide_in_air), nitrogen_dioxide in air (mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air), nitrogen_dioxide in air (mole_fraction_of_nitrogen_dioxide_in_air), nitrogen_dioxide in air (mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air), nitrogen_monoxide in air (mole_fraction_of_nitrogen_monoxide_in_air), nitrogen_monoxide in air (mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air), nitrogen_monoxide in air (mole_fraction_of_nitrogen_monoxide_in_air), nitrogen_monoxide in air (mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air), nitrogen_monoxide in air (mole_fraction_of_nitrogen_monoxide_in_air), nitrogen_monoxide in air (mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air), nitrogen_monoxide in air (mole_fraction_of_nitrogen_monoxide_in_air), nitrogen_monoxide in air (mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air)" />
  <attribute name="source" value="surface observation" />
  <attribute name="institution" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
  <attribute name="processing_level" value="processing_level_test" />
  <attribute name="date_created" value="2019-02-28T10:28:18 UTC" />
  <attribute name="date_metadata_modified" value="2019-02-28T10:28:18 UTC" />
  <attribute name="creator_name" value="Valerie Gros, Nicolas Bonnaire" />
  <attribute name="creator_type" value="person" />
  <attribute name="creator_email" value="valerie.gros@lsce.ipsl.fr, nicolas.bonnaire@lsce.ipsl.fr" />
  <attribute name="creator_institution" value="&quot;Laboratoire des Sciences du Climat et de l'Environnement, SIRTA, LSCE&quot;, &quot;Laboratoire des Sciences du Climat et de l'Environnement, SIRTA, LSCE&quot;" />
  <attribute name="contributor_name" value="Nicolas Pascal" />
  <attribute name="contributor_role" value="data submitter" />
  <attribute name="publisher_type" value="institution" />
  <attribute name="publisher_name" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_institution" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_email" value="ebas@nilu.no" />
  <attribute name="publisher_url" value="https://www.nilu.no/" />
  <attribute name="geospatial_bounds" value="POINT Z (48.709 2.159 162.0)" />
  <attribute name="geospatial_bounds_crs" value="EPSG:4979" />
  <attribute name="geospatial_lat_min" type="double" value="48.709" />
  <attribute name="geospatial_lat_max" type="double" value="48.709" />
  <attribute name="geospatial_lon_min" type="double" value="2.159" />
  <attribute name="geospatial_lon_max" type="double" value="2.159" />
  <attribute name="geospatial_vertical_min" type="double" value="162.0" />
  <attribute name="geospatial_vertical_max" type="double" value="162.0" />
  <attribute name="geospatial_vertical_positive" value="up" />
  <attribute name="time_coverage_start" value="2018-01-01T00:00:00 UTC" />
  <attribute name="time_coverage_end" value="2019-01-01T00:00:00 UTC" />
  <attribute name="time_coverage_duration" value="P0001-00-00T00:00:00" />
  <attribute name="time_coverage_resolution" value="P0000-00-00T01:00:00" />
  <attribute name="timezone" value="UTC" />
  <attribute name="ebas_data_definition" value="EBAS_1.1" />
  <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
  <attribute name="ebas_citation" value="Valerie Gros, Nicolas Bonnaire, nitrogen_dioxide, nitrogen_monoxide - chemiluminescence_photolytic at SIRTA Atmospheric Research Observatory, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/8Q72-YCBM" />
  <attribute name="ebas_set_type_code" value="TU" />
  <attribute name="ebas_timezone" value="UTC" />
  <attribute name="ebas_file_name" value="8Q72-YCBM.nc" />
  <attribute name="ebas_represents_doi" value="https://doi.org/10.48597/8Q72-YCBM" />
  <attribute name="ebas_contains_doi" value="https://doi.org/10.48597/8Q72-YCBM" />
  <attribute name="ebas_file_creation" value="2023-12-11T15:26:43.673050 UTC" />
  <attribute name="ebas_export_state" value="2019-10-18T07:49:40.950000 UTC" />
  <attribute name="ebas_export_filter" value="exclude-900,exclude-invalid" />
  <attribute name="ebas_startdate" value="20180101000000" />
  <attribute name="ebas_revision_date" value="20190228102818" />
  <attribute name="ebas_version" value="1" />
  <attribute name="ebas_version_description" value="initial revision" />
  <attribute name="ebas_data_level" value="2" />
  <attribute name="ebas_period_code" value="1y" />
  <attribute name="ebas_resolution_code" value="1h" />
  <attribute name="ebas_sample_duration" value="1h" />
  <attribute name="ebas_orig_time_res" value="1mn" />
  <attribute name="ebas_station_code" value="FR0020R" />
  <attribute name="ebas_platform_code" value="FR0020S" />
  <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
  <attribute name="ebas_station_latitude" value="48.70861111111111" />
  <attribute name="ebas_station_longitude" value="2.158888888888889" />
  <attribute name="ebas_station_altitude" value="162.0 m" />
  <attribute name="ebas_measuremenet_latitude" value="48.709" />
  <attribute name="ebas_measurement_longitude" value="2.159" />
  <attribute name="ebas_measurement_altitude" value="162.0 m" />
  <attribute name="ebas_measurement_height" value="3.0 m" />
  <attribute name="ebas_regime" value="IMG" />
  <attribute name="ebas_matrix" value="air" />
  <attribute name="ebas_laboratory_code" value="FR01L" />
  <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
  <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
  <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
  <attribute name="ebas_instrument_model" value="T200UP" />
  <attribute name="ebas_instrument_serial_number" value="56" />
  <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
  <attribute name="ebas_standard_method" value="None" />
  <attribute name="ebas_inlet_type" value="Hat or hood" />
  <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
  <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
  <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
  <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
  <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
  <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
  <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
  <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
  <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
  <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
  <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
  <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
  <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
  <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
  <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
  <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
  <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
  <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
  <attribute name="_NCProperties" value="version=2,netcdf=4.9.0,hdf5=1.12.2" />
  <attribute name="Metadata_Conventions" value="Unidata Dataset Discovery v1.0" />
  <attribute name="geospatial_lat_units" value="degrees_north" />
  <attribute name="geospatial_lon_units" value="degrees_east" />
  <attribute name="comment" value="{&#xA;    &quot;Data definition&quot;: &quot;EBAS_1.1&quot;,&#xA;    &quot;Data license&quot;: &quot;https://creativecommons.org/licenses/by/4.0/&quot;,&#xA;    &quot;Citation&quot;: &quot;Valerie Gros, Nicolas Bonnaire, nitrogen_dioxide, nitrogen_monoxide - chemiluminescence_photolytic at SIRTA Atmospheric Research Observatory, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/8Q72-YCBM&quot;,&#xA;    &quot;Set type code&quot;: &quot;TU&quot;,&#xA;    &quot;Timezone&quot;: &quot;UTC&quot;,&#xA;    &quot;File name&quot;: &quot;8Q72-YCBM.nc&quot;,&#xA;    &quot;Represents DOI&quot;: &quot;https://doi.org/10.48597/8Q72-YCBM&quot;,&#xA;    &quot;Contains data from DOI&quot;: &quot;https://doi.org/10.48597/8Q72-YCBM&quot;,&#xA;    &quot;File creation&quot;: &quot;2023-12-11T15:26:43.673050 UTC&quot;,&#xA;    &quot;Export state&quot;: &quot;2019-10-18T07:49:40.950000 UTC&quot;,&#xA;    &quot;Export filter&quot;: &quot;exclude-900,exclude-invalid&quot;,&#xA;    &quot;Startdate&quot;: &quot;20180101000000&quot;,&#xA;    &quot;Revision date&quot;: &quot;20190228102818&quot;,&#xA;    &quot;Version&quot;: &quot;1&quot;,&#xA;    &quot;Version description&quot;: &quot;initial revision&quot;,&#xA;    &quot;Data level&quot;: &quot;2&quot;,&#xA;    &quot;Period code&quot;: &quot;1y&quot;,&#xA;    &quot;Resolution code&quot;: &quot;1h&quot;,&#xA;    &quot;Sample duration&quot;: &quot;1h&quot;,&#xA;    &quot;Orig. time res.&quot;: &quot;1mn&quot;,&#xA;    &quot;Station code&quot;: &quot;FR0020R&quot;,&#xA;    &quot;Platform code&quot;: &quot;FR0020S&quot;,&#xA;    &quot;Station name&quot;: &quot;SIRTA Atmospheric Research Observatory&quot;,&#xA;    &quot;Station latitude&quot;: &quot;48.70861111111111&quot;,&#xA;    &quot;Station longitude&quot;: &quot;2.158888888888889&quot;,&#xA;    &quot;Station altitude&quot;: &quot;162.0 m&quot;,&#xA;    &quot;Measurement latitude&quot;: &quot;48.709&quot;,&#xA;    &quot;Measurement longitude&quot;: &quot;2.159&quot;,&#xA;    &quot;Measurement altitude&quot;: &quot;162.0 m&quot;,&#xA;    &quot;Measurement height&quot;: &quot;3.0 m&quot;,&#xA;    &quot;Regime&quot;: &quot;IMG&quot;,&#xA;    &quot;Matrix&quot;: &quot;air&quot;,&#xA;    &quot;Laboratory code&quot;: &quot;FR01L&quot;,&#xA;    &quot;Instrument type&quot;: &quot;chemiluminescence_photolytic&quot;,&#xA;    &quot;Instrument name&quot;: &quot;Teledyne_T200UP&quot;,&#xA;    &quot;Instrument manufacturer&quot;: &quot;Teledyne&quot;,&#xA;    &quot;Instrument model&quot;: &quot;T200UP&quot;,&#xA;    &quot;Instrument serial number&quot;: &quot;56&quot;,&#xA;    &quot;Method ref&quot;: &quot;FR01L_NOx_analysis&quot;,&#xA;    &quot;Standard method&quot;: &quot;None&quot;,&#xA;    &quot;Inlet type&quot;: &quot;Hat or hood&quot;,&#xA;    &quot;Inlet description&quot;: &quot;Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds&quot;,&#xA;    &quot;Ozone correction&quot;: &quot;Corrected for reaction with O3 in the inlet&quot;,&#xA;    &quot;Water vapor correction&quot;: &quot;Corrected for water vapor quenching in CLD&quot;,&#xA;    &quot;Humidity/temperature control&quot;: &quot;Nafion dryer&quot;,&#xA;    &quot;Humidity/temperature control description&quot;: &quot;passive, sample heated from atmospheric to lab temperature&quot;,&#xA;    &quot;Detection limit expl.&quot;: &quot;Determined by instrument counting statistics&quot;,&#xA;    &quot;Measurement uncertainty expl.&quot;: &quot;Determined by standard deviation of measurements&quot;,&#xA;    &quot;Zero/negative values code&quot;: &quot;Zero/negative possible&quot;,&#xA;    &quot;Zero/negative values&quot;: &quot;Zero and neg. values may appear due to statistical variations at very low concentrations&quot;,&#xA;    &quot;Organization&quot;: &quot;FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France&quot;,&#xA;    &quot;Framework acronym&quot;: &quot;ACTRIS, EMEP, GAW-WDCA&quot;,&#xA;    &quot;Framework name&quot;: &quot;European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols&quot;,&#xA;    &quot;Framework description&quot;: &quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.&quot;,&#xA;    &quot;Framework contact name&quot;: &quot;Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig&quot;,&#xA;    &quot;Framework contact email&quot;: &quot;clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no&quot;,&#xA;    &quot;Originator&quot;: &quot;Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France&quot;,&#xA;    &quot;Submitter&quot;: &quot;Pascal, Nicolas, , , , , , , , , &quot;,&#xA;    &quot;Acknowledgement&quot;: &quot;Request acknowledgement details from data originator&quot;&#xA;}" />
  <attribute name="standard_name_vocabulary" value="CF-1.7, ACDD-1.3" />
  <attribute name="history" value="None" />
  <attribute name="creator_url" value="ebas.nilu.no" />
  <attribute name="_CoordSysBuilder" value="ucar.nc2.internal.dataset.conv.CF1Convention" />
  <dimension name="time" length="8760" />
  <dimension name="tbnds" length="2" />
  <dimension name="metadata_time" length="1" />
  <dimension name="nitrogen_dioxide_nmol_per_mol_amean_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_ug_N_per_m3_amean_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_nmol_per_mol_prec1587_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_ug_N_per_m3_prec1587_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_nmol_per_mol_perc8413_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_ug_N_per_m3_perc8413_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_nmol_per_mol_stddev_qc_flags" length="3" />
  <dimension name="nitrogen_dioxide_ug_N_per_m3_stddev_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_nmol_per_mol_amean_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_ug_N_per_m3_amean_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_nmol_per_mol_prec1587_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_ug_N_per_m3_prec1587_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_nmol_per_mol_perc8413_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_ug_N_per_m3_perc8413_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_nmol_per_mol_stddev_qc_flags" length="3" />
  <dimension name="nitrogen_monoxide_ug_N_per_m3_stddev_qc_flags" length="3" />
  <group name="CFMetadata">
    <attribute name="time_coverage_start" value="2018-01-01T00:30:00Z" />
    <attribute name="time_coverage_end" value="2018-12-31T23:30:00Z" />
    <attribute name="time_coverage_units" value="seconds" />
    <attribute name="time_coverage_resolution" value="3600.0" />
    <attribute name="time_coverage_duration" value="P0Y0M364DT23H0M0.000S" />
  </group>
  <group name="NCISOMetadata">
    <attribute name="metadata_creation" value="2026-05-18" />
    <attribute name="nciso_version" value="2.4.8" />
  </group>
  <variable name="time_bnds" shape="time tbnds" type="double">
    <attribute name="long_name" value="time bounds for measurement" />
  </variable>
  <variable name="metadata_time_bnds" shape="metadata_time tbnds" type="double">
    <attribute name="long_name" value="time bounds for ebas metadata intervals" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_amean" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_dioxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_nmol_per_mol_amean_qc nitrogen_dioxide_nmol_per_mol_amean_ebasmetadata" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_calibration_scale" value="NPL+GPT" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_amean_qc" shape="nitrogen_dioxide_nmol_per_mol_amean_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_amean_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_amean" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_ug N_per_m3_amean_qc nitrogen_dioxide_ug N_per_m3_amean_ebasmetadata" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_calibration_scale" value="NPL+GPT" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_amean_qc" shape="nitrogen_dioxide_ug_N_per_m3_amean_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_amean_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_prec1587" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_dioxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_nmol_per_mol_prec1587_qc nitrogen_dioxide_nmol_per_mol_prec1587_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:15.87" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:15.87" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_prec1587_qc" shape="nitrogen_dioxide_nmol_per_mol_prec1587_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_prec1587_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_prec1587" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_ug N_per_m3_prec1587_qc nitrogen_dioxide_ug N_per_m3_prec1587_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:15.87" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:15.87" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_prec1587_qc" shape="nitrogen_dioxide_ug_N_per_m3_prec1587_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_prec1587_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_perc8413" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_dioxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_nmol_per_mol_perc8413_qc nitrogen_dioxide_nmol_per_mol_perc8413_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:84.13" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:84.13" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_perc8413_qc" shape="nitrogen_dioxide_nmol_per_mol_perc8413_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_perc8413_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_perc8413" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_ug N_per_m3_perc8413_qc nitrogen_dioxide_ug N_per_m3_perc8413_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:84.13" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:84.13" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_perc8413_qc" shape="nitrogen_dioxide_ug_N_per_m3_perc8413_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_perc8413_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_stddev" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_dioxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_nmol_per_mol_stddev_qc nitrogen_dioxide_nmol_per_mol_stddev_ebasmetadata" />
    <attribute name="cell_methods" value="time: standard_deviation" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="stddev" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_stddev_qc" shape="nitrogen_dioxide_nmol_per_mol_stddev_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_nmol_per_mol_stddev_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_stddev" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_dioxide_ug N_per_m3_stddev_qc nitrogen_dioxide_ug N_per_m3_stddev_ebasmetadata" />
    <attribute name="cell_methods" value="time: standard_deviation" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="stddev" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_stddev_qc" shape="nitrogen_dioxide_ug_N_per_m3_stddev_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_dioxide_ug_N_per_m3_stddev_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_amean" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_monoxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_nmol_per_mol_amean_qc nitrogen_monoxide_nmol_per_mol_amean_ebasmetadata" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_calibration_scale" value="NPL" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_amean_qc" shape="nitrogen_monoxide_nmol_per_mol_amean_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_amean_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_amean" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_ug N_per_m3_amean_qc nitrogen_monoxide_ug N_per_m3_amean_ebasmetadata" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_calibration_scale" value="NPL" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_amean_qc" shape="nitrogen_monoxide_ug_N_per_m3_amean_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_amean_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_prec1587" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_monoxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_nmol_per_mol_prec1587_qc nitrogen_monoxide_nmol_per_mol_prec1587_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:15.87" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:15.87" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_prec1587_qc" shape="nitrogen_monoxide_nmol_per_mol_prec1587_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_prec1587_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_prec1587" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_ug N_per_m3_prec1587_qc nitrogen_monoxide_ug N_per_m3_prec1587_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:15.87" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:15.87" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_prec1587_qc" shape="nitrogen_monoxide_ug_N_per_m3_prec1587_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_prec1587_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_perc8413" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_monoxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_nmol_per_mol_perc8413_qc nitrogen_monoxide_nmol_per_mol_perc8413_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:84.13" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:84.13" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_perc8413_qc" shape="nitrogen_monoxide_nmol_per_mol_perc8413_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_perc8413_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_perc8413" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_ug N_per_m3_perc8413_qc nitrogen_monoxide_ug N_per_m3_perc8413_ebasmetadata" />
    <attribute name="cell_methods" value="time: percentile:84.13" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="percentile:84.13" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_perc8413_qc" shape="nitrogen_monoxide_ug_N_per_m3_perc8413_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_perc8413_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_stddev" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_monoxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_nmol_per_mol_stddev_qc nitrogen_monoxide_nmol_per_mol_stddev_ebasmetadata" />
    <attribute name="cell_methods" value="time: standard_deviation" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="stddev" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020." />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_stddev_qc" shape="nitrogen_monoxide_nmol_per_mol_stddev_qc_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="nitrogen_monoxide_nmol_per_mol_stddev_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_stddev" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="nitrogen_monoxide_ug N_per_m3_stddev_qc nitrogen_monoxide_ug N_per_m3_stddev_ebasmetadata" />
    <attribute name="cell_methods" value="time: standard_deviation" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="20190228102818" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="initial revision" />
    <attribute name="ebas_statistics" value="stddev" />
    <attribute name="ebas_data_level" value="2" />
    <attribute name="ebas_sample_duration" value="1h" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="FR0020R" />
    <attribute name="ebas_platform_code" value="FR0020S" />
    <attribute name="ebas_station_name" value="SIRTA Atmospheric Research Observatory" />
    <attribute name="ebas_station_latitude" value="48.70861111111111" />
    <attribute name="ebas_station_longitude" value="2.158888888888889" />
    <attribute name="ebas_station_altitude" value="162.0 m" />
    <attribute name="ebas_measuremenet_latitude" value="48.709" />
    <attribute name="ebas_measurement_longitude" value="2.159" />
    <attribute name="ebas_measurement_altitude" value="162.0 m" />
    <attribute name="ebas_measurement_height" value="3.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="FR01L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="Teledyne_T200UP" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="56" />
    <attribute name="ebas_method_ref" value="FR01L_NOx_analysis" />
    <attribute name="ebas_standard_method" value="None" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="Air intake 1,5 m above the roof, On the roof of LSCE at about 8 meter of ground, PTFE tubing of 28 mm OD in a inox 316 sleeve, the sample line will not be heated, 1 manifold in PTFE, 1 turbo fan for residence time of the sample of few seconds" />
    <attribute name="ebas_ozone_correction" value="Corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="Nafion dryer" />
    <attribute name="ebas_humidity_temperaure_control_description" value="passive, sample heated from atmospheric to lab temperature" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit_expl" value="Determined by instrument counting statistics" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Determined by standard deviation of measurements" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="FR01L, Laboratoire des Sciences du Climat et de l'Environnement, LSCE-CNRS-CEA, CEA Orme des Merisiers, Bat 701, , 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_framework_acronym" value="ACTRIS, EMEP, GAW-WDCA" />
    <attribute name="ebas_framework_name" value="European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases, European Monitoring and Evaluation Programme, World Data Centre for Aerosols" />
    <attribute name="ebas_framework_description" value="ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme." />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre, Kjetil Tørseth, Markus Fiebig" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no, kt@nilu.no, Markus.Fiebig@nilu.no" />
    <attribute name="ebas_originator" value="Bonnaire, Nicolas, nicolas.bonnaire@lsce.ipsl.fr, Laboratoire des Sciences du Climat et de l'Environnement, LSCE, SIRTA, CEA Orme des Merisiers, Bat 701, 91191, Gif-sur-Yvette, France" />
    <attribute name="ebas_submitter" value="Pascal, Nicolas, , , , , , , , , " />
    <attribute name="ebas_acknowledgement" value="Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="SOP WP4_D4.2_M12.pdf ; detection limits NO=0.07020 nmol/mol; NO2=0.20318 nmol/mol -- Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_stddev_qc" shape="nitrogen_monoxide_ug_N_per_m3_stddev_qc_flags time" type="int">
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
  </variable>
  <variable name="nitrogen_monoxide_ug_N_per_m3_stddev_ebasmetadata" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="time" shape="time" type="double">
    <attribute name="long_name" value="time of measurement" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01 00:00:00 UTC" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="gregorian" />
    <attribute name="bounds" value="time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>
  <variable name="metadata_time" shape="metadata_time" type="double">
    <attribute name="long_name" value="time of ebas metadata intervals" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01 00:00:00 UTC" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="gregorian" />
    <attribute name="bounds" value="metadata_time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>